PT Should carried out as per article 6 of ASME Sec. V.
PT examination shall be performed in accordance with
the written procedure certified by Manufacturer to be in accordance with the
requirements of T-150 of ASME Sec. V
Evaluation of Indications (PT)
An indication is the evidence of a mechanical imperfection.
Only indications which have dimensions greater than 1/16” shall be considered
as relevant
A linear indication is one having a length greater
than three times the width.
A rounded indication is one of circular or
elliptical shape with a length equal to, or less than three times its width.
Any questionable or doubtful indications shall be
reexamined to determine whether or not they are relevant.
Acceptance standards (PT)
These acceptance standards shall apply unless
otherwise more restrictive standards are specified for specific material or applications
as specified in the PO Specifications.
All surfaces shall be free of
Relevant linear indications;
Relevant rounded indications greater than 3/16”
Four or more relevant indications in a line
separated by 1/16” or less, edge to edge
An indication of an imperfection may be longer than
the imperfection that causes it; however, the size of the indication is the basis
for the acceptance evaluation.